Zoll AED Pro Defibrillator

With innovative Real CPR Help?, See-Thru CPRTM, and ECG monitoring, the ZOLL? AED Pro? is a durable and dependable AED that exceeds all performance expectations.

SKU: 545 Category:

Rugged Construction, Advanced Capabilities
Designed with advanced capabilities, the ZOLL AED Pro supports Basic Life Support as well as Advanced Life Support professionals. A high-resolution LCD display allows responders to visualize a patient’s ECG.

Real CPR Help
The AED Pro is the first defibrillator designed for professional responders with real-time feedback on CPR chest compressions. ZOLL’s unique real-time feedback mechanism, Real CPR Help, includes a metronome set at the AHA recommended 100 bpm and a screen display that helps rescuers achieve optimum rate and depth of compression levels through audible and/or visual prompts.

See-Thru CPR
When the AED Pro is in manual mode and CPR chest compressions are being performed, See-Thru CPR is activated. See-Thru CPR reduces interruptions by allowing clinicians to see organized electrical activity while CPR compressions are being performed by filtering out compression artifact (“noise”). This allows rescuers the ability to see a patient’s underlying cardiac rhythm during resuscitation efforts and eliminates the need to stop compressions to see if defibrillation was successful.

Features
Simple design and exceptional urability expand early defibrillation programs in hospitals by supporting needs of Basic Life Support providers.
Manual override option satisfies Advanced Life Support professionals.
Electrodes and batteries compatible with ZOLL M Series? professional defibrillators for cost savings and ease-of-use.
Seven hours of internal memory data storage.
Wireless or USB data transfer.
Unrivaled battery compatibility and options (long-life disposable or rechargeable) that meet your specific needs.
Rate and depth feedback on CPR chest compressions ZOLL’s unique one-piece CPR-D padz.

General
Height: 9.2 inches (23.4 cm)
Width: 9.4 inches (23.9 cm)
Depth: 3 inches (7.6 cm)
Weight: < 6.5 lbs with disposable battery andelectrodes (2.9 kg). Design Standards: Meets or exceeds AAMI DF-80, EN 60601-1, EN 60601-1-2. Patient Safety: All patient connections are electrically isolated. Environmental Temperature Operating: 0?C to 50?C Storage and Shipping: 30?C to 70?C Humidity: 10% to 95% relative humidity, noncondensing Vibration: MIL-STD-810F, Integrity Test for Helicopters Shock: IEC 60068-2-27; 100G Altitude Height: 300 to 15,000 ft; 91 to 4573 m Pressure: 768 to 429 mmHg; 1024 to 572 millibars Particle and Water Ingress: IEC 60529, IP 55 Drop Test: 1.5 m per IEC 68-2-32 Defibrillator Waveform: ZOLL rectilinear biphasic waveform Energy Selection: Configurable preset energy levels for adult and pediatric patients in three-shock stacks. Charge Time: Less than 10 seconds with a new, fully charged battery; with depleted battery packs, the charge time will be longer. For the fifteenth discharge at maximum energy (200 joules), the charge time is less than 10 seconds. Charge Hold Time: Semiautomatic mode: 30 seconds Manual mode: 60 seconds Energy Display: Display screen shows selected energy level (manual mode only). Charge Controls Semiautomatic Mode: Automated Manual Mode: Softkey Defibrillation Electrode Pads ZOLL Single-Use, Pregelled Electrode Pads: CPR-D padz (includes CPR sensor) Adult statpadz II, Pediatric pedipadz II Built-in Defibrillator self-test: Verifies proper charging and discharging of the defibrillator. Defibrillation Advisory: Evaluates electrode attachment and patient ECG to determine if defibrillation is needed. Shockable Arrhythmia: Ventricular fibrillation (VF) with amplitude greater than 100 ?V Wide-complex ventricular tachycardia (VT) Adult: Greater than 150 beats per minute Pediatric: Greater than 200 beats per minute Valid Patient Impedance Range: 10? to 300? CPR Monitoring Compression Depth: 0.75 to 3 inches ?0.25 inches (1.9 to 7.6 cm ?0.6 cm) Compression Rate: 50 to 150 compressions per minute ECG Monitoring Input Protection: Fully defibrillation-protected. Bandwidth: 1.4 to 22 Hz with defibrillation electrode cable 1.4 to 22 Hz (default) with AED Pro ECG cable; 0.7 to 30 Hz as a configurable option ECG Lead: Lead II ECG Amplitude Range: ?5 mV Heart Rate Range: 30 to 300 beats per minute Heart Rate Accuracy: ?5 beats per minute Heart Rate Resolution: 1 beat per minute Heart Rate Alert: Configurable low heart rate limit in the range 30 to 100 beats per minute Off Data Recording & Storage Type: Nonvolatile memory Capacity: 7 hours of ECG data Display Screen Display Type: Liquid crystal display (LCD) High resolution, 320 pixels by 240 pixels Viewable Area: 2.27 in 3.02 in (5.76 cm 7.68 cm) Sweep Speed: 25 mm/s ?5% Viewing Time: 2.96 seconds (if CPR gauge displayed) 3.2 seconds (without CPR gauge) Sealed Lead Acid Type: Rechargeable sealed lead acid Weight: 2.2 lbs. (1 kg) Nominal Voltage: 10 V Recharge Time: 4 hours or less with: ZOLL Base PowerCharger 4x4 ZOLL Base PowerCharger 1x1 Operating Time For a new, fully charged battery pack at 20?C:170 defibrillator discharges at maximum energy (200 joules) or 6 hours of continuous ECG monitoring. The CHANGE BATTERY warning appears after 115 maximum-energy discharges. Standby life: 3 months before recharge or retest