Waveline EZ Portable Patient Monitor with Touch-Screen

Extremely portable, feature rich, touch-screen monitor.
ECG, Respiration, SpO2, Noninvasive BP and Temperature. Available with EtCO2 and printer ? Now with Masimo SET?/Nellcor Pulse Oximetry (optional upgrade)
Featuring cutting-edge innovations and impeccable craftsmanship, the Avante Waveline EZ patient monitor is the perfect choice for health care professionals who demand precision, performance and affordability. It features an intuitive touchscreen that helps you quickly and accurately evaluate patient conditions, resulting in better patient care. Utilize the Waveline EZ to monitor ECG, respiration, SpO2, NIBP and temperature; it’s also available with EtCO2 monitoring and a printer.

SKU: 597 Category:

Weighs only 6 lbs. One of the most mobile multi parameter monitors on the market.
Touch-screen provides immediate operation
8 inch high resolution color display.
Simultaneous multi-lead ECG monitoring
Advanced ST and arrhythmia detection
Graphical and tabular trending
Displays five waveforms
Battery backup
Audible and visual alarms
Quick BP readings recall
New – Masimo SET? Pulse Oximetry ? ask your Avante representative for details
New – Bigger time stamp in upper right corner
New – Standby button
New – Revised SpO2 pitch tone is still audible when SpO2 rate decreases.
New – Volume and Sounds are adjustable and now can be turned off completely
New – Option to print Numerical Data Only
New – Color of the waveforms can be changed

Physical Dimensions
Height: ~8-1/5 inches
Width: 9 inches
Depth: 4-7/10 inches
Safety Approval & Quality System
Designed to meet IEC60601-1-1988, EN60601-1-1, EN60601-2
Class II Equipment, double insulated
Type BF applied parts
ISO9001 & EN46001 Certified
Power Requirements
Power Supply AC 90-264V/47-63Hz
Input Power ?55VA
Fuses Two fuse sockets in the rear panel indicated by “FUSE”, OI 5X20, 2A/250V
Battery 12V/4.0AH sealed lead-acid
Charge time ?4 hours
Operating time ?2 hours (full recharge)
Battery Charging Method Automatic
charging after monitor is connected to AC power supply (with charge protection function)
Discharge Protection When powered by battery, the monitor will be automatically turned off when battery power is almost used up
ECG
Input -3-lead ECG cable and standard AAMI line for connection
Input – (Optional) 5-lead ECG cable and standard AAMI line for connection
Patient Safety Standard IEC60601-1-1988
CMRR ?60dB (Common Mode Rejection Ratio)
Heart Rate Range 20 ~ 254bpm ? 1bpm
Heart Rate Averaging 8 second average
ST Segment Range -0.8 ~ + 0.8mV
Interface AAMI 6-pin
Lead Selection I, II, III (3 lead mode)
I, II, III, aVR, aVL, aVF, V (5 lead mode) (ST and Arrhythmia analysis)
Lead Fault Alarm Audible, Visual Input 5-lead ECG patient cable
QRS Indicator Audible and Visual Alert
Waveform Storage 6 minutes
Sweep Speed 12.5/25/50 mm/sec
Gain Selection 4mV, 2mV, 1mV, 0.5mV, 0.25mV,Auto
Trends 2 hours -> 4 hours -> 8 hours -> 24 hours -> 48 hours
Patient Isolation Breakdown voltage 4000VAC 50Hz 60 seconds Leakage current <10?A Frequency width Monitoring mode 0.5 ~ 40Hz (+0.4dB,-3.0dB) Surgery mode 0.5 ~ 20Hz (+0.4dB, -3.0dB) not calibration significant Patient Drive Current <10?A Enclosure Leakage Current <0.1mA Maximum T Wave Rejection Capability 1.2mV Heart Rate Alarm Response Time < 7 seconds Aspect Ratio 0.24 ~ 0.6 sec/mV Alarm Frequency Low alarm: 2-2.4kHz High alarm: 3-3.4kHz Defibrillator Protected & ESIS Protected Tested with 5kV Recovery Time Following Defibrillation 0.02 % Pulse Amplitude and % Transmission >5
SpO2: ?2 %
PR: ?3 bpm
Modes:
Averaging mode: 2,4,8,10,12,14 and 16 s
Sensitivity: Normal, APOD and Maximum
PR Accuracy (non-motion):
Neonate: 70?100 %: ? 3 %, 0?69 % : unspecified
Adult Pediatric Neonate: 25?240 bpm: ?3 bpm
PR Accuracy (motion):
Adult Pediatric Neonate: 25?240 bpm: ?5 bpm
Measuring Range:
SpO2: 1?100 %
PR: 25?240 bpm
Perfusion: 0.02?20 %
Non-Invasive Blood Pressure (NIBP)
Method Automatic oscillometric
Parameters Systolic, diastolic, mean arterial pressure, pulse
Scale mmHg or kPa
Operating Modes Manual, Automatic, Continuous
Repeat Cycles 1 ~ 10, 15, 30, 60, 90, 120 minutes
Determination Systolic, Adult/pediatric 40 ~ 250mmHg (5.3 ~ 33.3kPa) Systolic, Neonate 20 ~ 160mmHg (2.7 ~ 21.3kPa) Diastolic, Adult/pediatric 10 ~ 180mmHg (1.3 ~ 24.0kPa) Diastolic, Neonate 10 ~ 140mmHg (1.3 ~ 18.7kPa)
Cuff Pressure Range Adult/pediatric 0 ~ 300mmHg (0 ~ 40.0kPa) Neonate 0 ~ 140mmHg (0 ~ 18.7kPa)
Initial Cuff Inflation Adult/pediatric 170?10mmHg (22.7?1.3kPa) Neonate 100?10mmHg (16.0?1.3kPa)
Deflation Pressure 30mmHg(4.0kPa) higher than the last systolic pressure
Cuff Inflation Rate No greater than 50mmHg/sec
Measurement Time Typical 25 seconds, Maximum 40 seconds, Typical Stat 20 seconds
Pressure Display Accuracy ?3mmHg
BP Pulse Rate Accuracy ?2% @ 40 ~240bpm
Cuff Neonate, infant, pediatric, standard adult